	<entry>
		<id>http://wiki.makespace.org/index.php?title=Formal_Risk_Assessment:_EggBot&amp;diff=27962&amp;oldid=prev</id>
		<title>Zoomzoomluke: Created page with &quot; = Formal Risk Assessment for the EggBot =  ===Activity===  The EggBot is able move a tool around a spherical work piece according to computer control. In typical use this wou...&quot;</title>
		<link rel="alternate" type="text/html" href="http://wiki.makespace.org/index.php?title=Formal_Risk_Assessment:_EggBot&amp;diff=27962&amp;oldid=prev"/>
				<updated>2015-02-03T13:53:59Z</updated>
		
		<summary type="html">&lt;p&gt;Created page with &amp;quot; = Formal Risk Assessment for the EggBot =  ===Activity===  The EggBot is able move a tool around a spherical work piece according to computer control. In typical use this wou...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&lt;br /&gt;
= Formal Risk Assessment for the EggBot =&lt;br /&gt;
&lt;br /&gt;
===Activity=== &lt;br /&gt;
The EggBot is able move a tool around a spherical work piece according to computer control. In typical use this would involve moving a pen across the surface an egg or other material with the intention of drawing a chosen design.&lt;br /&gt;
&lt;br /&gt;
Other tools can be used, such as a engraving tool or hot wax tool.&lt;br /&gt;
&lt;br /&gt;
===Hazard identification===&lt;br /&gt;
* Changing, installing or operating using the diamond engraving tool exposes the sharp blade. The blade is approx. 1mm long with a sharp tip. This could cause the operator a minor stab wound or a cut if handled improperly.&lt;br /&gt;
* Cables (mains power and USB) could be a trip hazard for the operator or those walking past the machine.&lt;br /&gt;
* The pen arm moves horizontally on the machine and could trap fingers.&lt;br /&gt;
* The pen arm is moved vertically in the machine and could trap fingers. &lt;br /&gt;
* The accessories are very small and can be sharp. Usual risk if swallowed or mishandled.&lt;br /&gt;
&lt;br /&gt;
===Persons at risk===&lt;br /&gt;
* Operator of the machine&lt;br /&gt;
* Other users of the craft room, especially children&lt;br /&gt;
&lt;br /&gt;
===Initial assessment of risk===&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
 |-&lt;br /&gt;
!|Hazard identified	&lt;br /&gt;
!|Severity	&lt;br /&gt;
!|Probability	&lt;br /&gt;
!|Risk Factor&lt;br /&gt;
 |-&lt;br /&gt;
 |Using the diamond engraver exposes the sharp blade&lt;br /&gt;
 |2&lt;br /&gt;
 |2&lt;br /&gt;
 |4&lt;br /&gt;
 |-&lt;br /&gt;
 |Cables (mains power and USB) could be a trip hazard&lt;br /&gt;
 |1&lt;br /&gt;
 |1&lt;br /&gt;
 |1&lt;br /&gt;
 |-&lt;br /&gt;
 |Pen arm moves horizontally on the machine, could trap fingers&lt;br /&gt;
 |2&lt;br /&gt;
 |2&lt;br /&gt;
 |2&lt;br /&gt;
 |-&lt;br /&gt;
 |Pen arm is moved vertically on machine, could trap fingers&lt;br /&gt;
 |1&lt;br /&gt;
 |1&lt;br /&gt;
 |1&lt;br /&gt;
 |-&lt;br /&gt;
 |Accessories are very small, can be sharp&lt;br /&gt;
 |1&lt;br /&gt;
 |2&lt;br /&gt;
 |2&lt;br /&gt;
 |}&lt;br /&gt;
&lt;br /&gt;
Categorising the risk level as 1-4(Low), 5-9(Moderate), 10-15(High) or 16-25 (Unacceptable) shows that the potential level of risk in this activity is '''low'''.  &lt;br /&gt;
Further measures are '''not needed''' to reduce the risk to an acceptable level, but are considered anyway.&lt;br /&gt;
&lt;br /&gt;
===Control measures===&lt;br /&gt;
Necessary control measures arising from the hazards identified are:&lt;br /&gt;
* A poster near the machine details the correct method for handling all accessories and procedure for changing the tools.&lt;br /&gt;
* The equipment summary sheet near the machine advises caution.&lt;br /&gt;
* Cables will be routed and secured to ensure there is insufficient slack to provide a risk.&lt;br /&gt;
&lt;br /&gt;
===Final assessment of risk===&lt;br /&gt;
The assessed risk taking into account the implementation of the control measures listed, and adherence to the SSOW (Safe System of Work) if applicable is as follows: &lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
 |-&lt;br /&gt;
!|Hazard identified	&lt;br /&gt;
!|Severity	&lt;br /&gt;
!|Probability	&lt;br /&gt;
!|Risk Factor&lt;br /&gt;
 |-&lt;br /&gt;
 |Using the diamond engraver exposes the sharp blade&lt;br /&gt;
 |tbd&lt;br /&gt;
 |tbd&lt;br /&gt;
 |tbd&lt;br /&gt;
 |-&lt;br /&gt;
 |Cables (mains power and USB) could be a trip hazard&lt;br /&gt;
 |tbd&lt;br /&gt;
 |tbd&lt;br /&gt;
 |tbd&lt;br /&gt;
 |-&lt;br /&gt;
 |Pen arm moves horizontally on the machine, could trap fingers&lt;br /&gt;
 |tbd&lt;br /&gt;
 |tbd&lt;br /&gt;
 |tbd&lt;br /&gt;
 |-&lt;br /&gt;
 |Pen arm is moved vertically on machine, could trap fingers&lt;br /&gt;
 |tbd&lt;br /&gt;
 |tbd&lt;br /&gt;
 |tbd&lt;br /&gt;
 |-&lt;br /&gt;
 |Accessories are very small, can be sharp&lt;br /&gt;
 |tbd&lt;br /&gt;
 |tbd&lt;br /&gt;
 |tbd&lt;br /&gt;
 |}&lt;br /&gt;
&lt;br /&gt;
The risk now falls into the category '''tbd''' and is considered to be tbd.&lt;br /&gt;
&lt;br /&gt;
Authorised by &lt;br /&gt;
	&lt;br /&gt;
Sign:	&lt;br /&gt;
&lt;br /&gt;
Print:	&lt;br /&gt;
&lt;br /&gt;
Date:&lt;/div&gt;</summary>