(Created page with "== Ultimaker Maintenance == '''To be performed by Ultimaker Owners only''' == Weekly: == * Test print to check build plate is level * Check filament feed tube is fully hom...")
 
(Maintenance Log:)
Line 28: Line 28:
 
See log book with Ultimaker for details.
 
See log book with Ultimaker for details.
  
Additional maintenance performed:
+
'''Additional maintenance performed:'''
  
Replaced PTFE Coupler and nozzle, levelled build plate. Filament had not been feeding properly. PTFE coupler notably burnt (Stephen Harrison 2015-11-25). Print Time: 425H (484M)
+
* Replaced PTFE Coupler and nozzle, levelled build plate. Filament had not been feeding properly. PTFE coupler notably burnt (Stephen Harrison 2015-11-25). Print Time: 425H (484M)

Revision as of 14:40, 26 November 2015

Ultimaker Maintenance

To be performed by Ultimaker Owners only


Weekly:

  • Test print to check build plate is level
  • Check filament feed tube is fully home (No visible ring around tube above white push fit fitting)
  • Clean build plate
  • Clean base of printer (under/around build place)
  • Clean desk
  • Remove old files from SD Card
  • Check print removal tool available and in good condition


As Needed:


Maintenance Log:

See log book with Ultimaker for details.

Additional maintenance performed:

  • Replaced PTFE Coupler and nozzle, levelled build plate. Filament had not been feeding properly. PTFE coupler notably burnt (Stephen Harrison 2015-11-25). Print Time: 425H (484M)